A7 - Jumper Terminals A to F
^ Jumper A to F terminal at EVR connector.
^ Voltage should read a minimum of 0.5 volts over base voltage, with load test conditions in effect.
Less than 0.5 volt -- Go to A8. A8 - Jumper Bat to Fld Terminals
0.5 volt or more on vehicles with alternator warning lamp -- Go to A10. A10 - Check For Power at S and I Terminals
0.5 volt or more on vehicles with ammeter -- Go to A11. A11 - Check For Power to S Terminal